Level 1 sweep and inspection to the NFPA 211 annual standard - flue, crown, cap, and flashing checked and photographed
Chimney sweep logs do not sweep chimneys. They loosen some creosote - which then falls where a brush and vacuum still have to collect it.
Gelco Flue Liner Replacement: The Denver Owner’s Guide
We stock and install Gelco-compatible flue liner replacement in Denver, with typical installed pricing running $2,800-$5,400 depending on height, diameter, and whether your existing tee and top plate can be reused. Most Gelco liner swaps we book in Capitol Hill, Highlands, and Wash Park are completed in a single day once the written scope is approved. Homeowners usually discover the failure during a sweep when the camera shows gaps, corrosion scaling, or orange peel pitting in the stainless wall, or when they spot water staining on the firebox after a spring snow followed by a rapid Denver thaw.
Which Gelco Models This Applies To
Gelco’s flue liner program breaks into two main series: the older Gelco-Pro round flexible liners (common in 1980s-2000s Denver builds, especially in Park Hill and Congress Park brick Victorians) and the current Gelco UL-listed 316Ti stainless line with the ribbed-wall design. The Pro series used a .005-inch wall thickness and a distinct crimped collar at the tee; current 316Ti runs .006-inch minimum with a welded seam and a different top plate bolt pattern. We source both OEM Gelco and compatible aftermarket equivalents through our Haven buying network, and the choice depends on what your existing top termination and tee look like. If your label is readable, the part number prefix tells the story: GPRO- for the legacy line, G316- for current production. When the label’s burned off, we measure inner diameter to the nearest eighth-inch and check wall rigidity with a bend test. Mixing a Pro-series tee with a 316Ti liner body will leak at the collar; we’ve caught that mismatch three times in Berkeley bungalows this past year alone.
Signs Your Gelco Flue Liner Replacement Is Failing

- Orange peel pitting on the camera scan. This is localized corrosion from acidic condensation, common in Denver’s dry climate where rapid temperature swings stress the stainless. The pits don’t seal, and each one is a starting point for a through-wall breach.
- White or green scaling at joints. Salt deposits mean flue gases are escaping at a tee or seam, usually because the original Pro-series crimp has worked loose after 15-20 years of expansion cycling.
- Water staining below the damper after spring snow. A compromised liner allows melt to track down the flue wall instead of shedding at the crown. In Denver’s March-April freeze-thaw cycles, this accelerates rust at the smoke shelf.
- Smoke smell in upper rooms during wind. A perforated liner near the top lets exhaust pressurize the chase cavity; older Stapleton and Lowry rebuilds with stucco chases show this pattern when the Gelco top plate gasket has hardened.
- Your sweep flags “liner movement” on the report. If the liner has dropped from its original top support, the bottom tee may no longer seat in the thimble, creating a direct path for CO into the basement.
Before
AfterReplacement Cost & What’s Included
| Scope | Price Range |
|---|---|
| Gelco liner replacement, 15-25 ft, reuse existing tee/top plate | $2,800-$3,600 |
| Gelco liner replacement with new tee and top plate | $3,800-$4,800 |
| Full liner + smoke chamber parge + new cap assembly | $4,600-$5,400 |
The spread comes down to three things: chimney height (a three-story Baker or Sunnyside row house adds 8-10 feet over a ranch), whether we can salvage your Gelco tee and top plate, and if the smoke chamber needs parge coating to restore proper draft geometry. Every quote is itemized in writing before work starts, per Haven Standard Clause 1. The liner itself carries a lifetime warranty; our labor is covered by the 365-Day Done Right Promise. Materials come through our Haven buying network from Gelco, DuraFlex, HeatShield, and Olympia Chimney, procured specifically to keep customer prices honest.
DIY or Call Us?

You can safely verify your Gelco model number from the attic or roof if you’re comfortable on a ladder and the pitch is walkable. Check the top plate label and snap a photo of any part stamping. Do not attempt to pull the liner yourself. Gelco flexible liners are tension-set at the top support; releasing that without proper anchoring can drop the entire run into the firebox, and the stainless edge is sharp enough to open a hand to the bone. More critically, a liner pulled without CO monitoring and proper chase sealing can leave exhaust leaking into wall cavities overnight. We pull, inspect, and replace with the camera running the full length both directions. The camera doesn’t guess. Neither do we. Call (720) 674-7312 when you’re ready for the written scope.
FAQs
A properly installed Gelco 316Ti liner should last 20-30 years in Denver’s climate, though we’ve seen Pro-series liners fail at 12-15 years in high-usage fireplaces that burn green softwood. The dry air here isn’t the killer; it’s the rapid temperature swing from below-zero nights to 60-degree afternoons that fatigues the metal. Annual inspection with a camera scan catches degradation before it’s a safety issue. Call (720) 674-7312 to schedule - estimates are free.
Localized damage can sometimes be addressed with a HeatShield cerfractory flue sealant application if the breach is under 3 inches and not at a joint, but Gelco’s flexible corrugated wall doesn’t take a patch the way a smooth rigid liner would. We camera-scan to determine if the damage pattern is patchable; if more than 30% of the run shows pitting or any joint is compromised, replacement is the only code-compliant fix. Call (720) 674-7312 and we’ll show you the footage.
Most Gelco liner replacements in Denver are completed in 4-6 hours of on-site work, booked as a single day. Tall chimneys in Cherry Creek or Hilltop with multiple offsets may run into a second day. We deliver a written price before we start, assign a named technician, and text you when they’re en route. You receive the camera footage, photos, and completed scope documentation before we leave.
We stock the most common Gelco diameters (6-inch and 8-inch round) and standard tee assemblies on our Denver trucks, sourced through our Haven buying network alongside DuraFlex and HeatShield materials. Odd sizes or the legacy Pro-series collar require a next-day pull from our supplier. We’ll confirm availability when you call (720) 674-7312 so you’re not waiting on parts.
Level Two Chimney Denver is an independent service provider and is not affiliated with Gelco. We install OEM and compatible aftermarket flue liner systems under the Haven Standard.
Ready for a written price? Call (720) 674-7312. A live person answers 24 hours a day, and we’ll schedule your NFPA 211 Level 2 camera inspection with a documented photo record - Clause 4 of the Haven Standard, included on every visit since 2009. Bring us any competitor’s written estimate for a free second opinion.
Written by Corrine Halstead, Owner, Level Two Chimney Denver at Level Two Chimney Denver, serving Denver and nearby areas.